Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Phys Rev Lett ; 129(11): 114801, 2022 Sep 09.
Artículo en Inglés | MEDLINE | ID: mdl-36154426

RESUMEN

Premature relativistic transparency of ultrathin, laser-irradiated targets is recognized as an obstacle to achieving a stable radiation pressure acceleration in the "light sail" (LS) mode. Experimental data, corroborated by 2D PIC simulations, show that a few-nm thick overcoat surface layer of high Z material significantly improves ion bunching at high energies during the acceleration. This is diagnosed by simultaneous ion and neutron spectroscopy following irradiation of deuterated plastic targets. In particular, copious and directional neutron production (significantly larger than for other in-target schemes) arises, under optimal parameters, as a signature of plasma layer integrity during the acceleration.

2.
Phys Rev Lett ; 116(7): 075001, 2016 Feb 19.
Artículo en Inglés | MEDLINE | ID: mdl-26943539

RESUMEN

Plasma-based laser amplification is considered as a possible way to overcome the technological limits of present day laser systems and achieve exawatt laser pulses. Efficient amplification of a picosecond laser pulse by stimulated Brillouin scattering (SBS) of a pump pulse in a plasma requires to reach the self-similar regime of the strongly coupled (SC) SBS. In this Letter, we report on the first observation of the signatures of the transition from linear to self-similar regimes of SC-SBS, so far only predicted by theory and simulations. With a new fully head-on collision geometry, subpicosecond pulses are amplified by a factor of 5 with energy transfers of few tens of mJ. We observe pulse shortening, frequency spectrum broadening, and down-shifting for increasing gain, signatures of SC-SBS amplification entering the self-similar regime. This is also confirmed by the power law dependence of the gain on the amplification length: doubling the interaction length increases the gain by a factor 1.4. Pump backward Raman scattering (BRS) on SC-SBS amplification has been measured for the first time, showing a strong decrease of the BRS amplitude and frequency bandwidth when SBS seed amplification occurs.

3.
Rev Sci Instrum ; 86(7): 073308, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26233373

RESUMEN

Calibration of three scintillators (EJ232Q, BC422Q, and EJ410) in a time-of-flight arrangement using a laser drive-neutron source is presented. The three plastic scintillator detectors were calibrated with gamma insensitive bubble detector spectrometers, which were absolutely calibrated over a wide range of neutron energies ranging from sub-MeV to 20 MeV. A typical set of data obtained simultaneously by the detectors is shown, measuring the neutron spectrum emitted from a petawatt laser irradiated thin foil.


Asunto(s)
Calibración , Rayos Láser , Neutrones , Análisis Espectral
4.
Phys Rev Lett ; 115(5): 054802, 2015 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-26274423

RESUMEN

The production of neutron beams having short temporal duration is studied using ultraintense laser pulses. Laser-accelerated protons are spectrally filtered using a laser-triggered microlens to produce a short duration neutron pulse via nuclear reactions induced in a converter material (LiF). This produces a ∼3 ns duration neutron pulse with 10(4) n/MeV/sr/shot at 0.56 m from the laser-irradiated proton source. The large spatial separation between the neutron production and the proton source allows for shielding from the copious and undesirable radiation resulting from the laser-plasma interaction. This neutron pulse compares favorably to the duration of conventional accelerator sources and should scale up with, present and future, higher energy laser facilities to produce brighter and shorter neutron beams for ultrafast probing of dense materials.

5.
Rev Sci Instrum ; 85(9): 093303, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25273715

RESUMEN

A novel method for characterising the full spectrum of deuteron ions emitted by laser driven multi-species ion sources is discussed. The procedure is based on using differential filtering over the detector of a Thompson parabola ion spectrometer, which enables discrimination of deuterium ions from heavier ion species with the same charge-to-mass ratio (such as C(6+), O(8+), etc.). Commonly used Fuji Image plates were used as detectors in the spectrometer, whose absolute response to deuterium ions over a wide range of energies was calibrated by using slotted CR-39 nuclear track detectors. A typical deuterium ion spectrum diagnosed in a recent experimental campaign is presented, which was produced from a thin deuterated plastic foil target irradiated by a high power laser.

6.
Phys Rev Lett ; 111(18): 185001, 2013 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-24237527

RESUMEN

The interaction of laser pulses with thin grating targets, having a periodic groove at the irradiated surface, is experimentally investigated. Ultrahigh contrast (~10(12)) pulses allow us to demonstrate an enhanced laser-target coupling for the first time in the relativistic regime of ultrahigh intensity >10(19) W/cm(2). A maximum increase by a factor of 2.5 of the cutoff energy of protons produced by target normal sheath acceleration is observed with respect to plane targets, around the incidence angle expected for the resonant excitation of surface waves. A significant enhancement is also observed for small angles of incidence, out of resonance.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...